PERSONAL BREATHALYSERPERSONAL BREATHALYSER 1817
The AlcoSense Alcohol Interlock is a hand-held breathalyser with a
vehicle ignition system. The driver must complete a breath alcohol test,
with a result below a preset limit, before they can start the vehicle.
Installing the AlcoSense Alcohol Interlock is necessary to prevent
alcohol-impaired persons from operating motor vehicles, heavy
equipment or machinery. This helps to safeguard others and prevent
accidents caused by drink driving.
The AlcoSense Alcohol Interlock, with its microprocessor-controlled
operation, exceeds NHTSA specications. The heated electrochemical
fuel cell and breath sample pathways provide an extremely reliable and
accurate measurement.
The AlcoSense Alcohol Interlock is designed with an absolute 100%
detection of vehicle operation without a breath sample, making it the
most dependable and precise ignition interlock device oered on the
market today.
Complex data retention capability and uploading features simplify data
management and information analysis.
Breathalyser Specifications
Indication of %BAC 0.000% to 0.400% BAC
Accuracy ± 0.005% at 0.100% BAC
Warm-Up Time N/A
Response Time N/A
Recycle Time N/A
Mouthpiece Only compatible with AlcoSense
mouthpiece
Sensor Type Electrochemical fuel cell sensor
Power Supply N/A
Weight 280g (sample head only)
Dimensions (mm) 55 high x 315 wide x 435 deep
Remarks • Calibration reminder
• Extreme temperature tolerance
• Multi-language
Calibration Australian Standards Requirement: 60 days
Eectively reduces the risk of drink driving
FR90000 INTERLOCK
Australian Standard AS3547 Certied
Certied to AS3547 for accuracy and reliability. The FR9000 is
ideal for personal and workplace use.
Voice Commands
Loud and clear voice indicator to notify driver of several events
such as rolling test
Data Input
Onboard date logger records every interaction the driver has
with the vehicle including activity, time, date and BAC level.
The computer can store more than 8,000 (can be upgraded)
separate events and display the content in a summary of
detailed format.
Meeting Reminder
Meeting minder uses audio and visual reminders to count the
days between required scheduled appointments. If the driver
misses his or her appointment, the service calendar will
disable the interlock device, preventing the car from starting.
Circumvention Records
If the interlock device detects a bypass, or detects a failed
rolling retest, the FR9000W will record all events in the
circumvention record log.
Emergency Restart
In case of a vehicle stall, this feature allows the vehicle to have
an emergency restart within several minutes of shutdown.
Power Interrupt
Records when the vehicle’s power has been disconnected
or interrupted. This may occur if the driver tampers, repairs
or replaces the battery. Driver is required to provide a
documentation of repairs.
Data Transfer
Supports infrared, RS232, and USB download for data and
reports.
The AlcoSense AccessPoint controls the entry of employees
into their workplace using a simple breath alcohol test.
Easily installed to turnstiles, automatic doors, speed gates,
and other types of access control systems.
Fuel Cell Accuracy
Highly sensitive and accurate, the AlcoSense AccessPoint is
highly eective at helping to enhance and execute workplace
OH&S policies eciently even before an employee steps
into the workplace. It is ideal for industries where a strict or
zero alcohol tolerance policy is observed, such as factories,
construction and mining sites, chemical plants, casinos,
workplaces that use heavy machinery, laboratories and
hospitals, and stadiums.
Replaceable Sensor Module
The AlcoSense AccessPoint has a replaceable fuel cell
sensor module, making it highly convenient and easy to use
and maintain.
Industrial Breathalyser
Ideal for all types of workplaces including work sites,
laboratories, factories and hospitals. The unit is easy for
employees to use and can test up to 12 people in 1 minute.
Fast Results
Testing is easy as employees only need to blow into the
sampling hole - no mouthpieces or straws are required..
Test results are displayed simply as ‘Pass’ if no alcohol is
detected, or ‘Fail’ if alcohol is detected. Users that pass the
breath test are allowed to enter, whereas users that fail the
breath test are denied access through the door. The “Pass”
range can also be adjusted from 0.01 to 0.09%BAC.
Install with any access control system
The AccessPoint breathalyser can be installed with
turnstiles, automatic doors, speed gates, and any other type
of access control system.
Breathalyser Specifications
Indication of %BAC N/A
Accuracy ± 0.01% at 0.05%BAC
Warm-Up Time 3 seconds - 4 minutes
Response Time 3 - 10 seconds
Recycle Time N/A
Mouthpiece Not required
Sensor Type Replaceable Fuel Cell Sensor
Power Supply Replaceable Fuel Cell Sensor
Weight 674g
Dimensions (mm) 100 high x 44 wide x 15 deep
Result Reading Test result indicated by LED display
PASS : Indicate Green Lamp
FAIL : Indicate Red Lamp
(Level for PASS can be adjusted)
Calibration N/A
Ensures workplace safety
ACCESSPOINT
Turn the car on and
wait for breathalyser
to warm up
Blow into breathalyser
Start car engine